SM511 Output Module
Contact Info
- Add:陸家嘴軟件園, Zip: 210000
- Contact: 韓工
- Tel:13391283569
- Email:690005835@qq.com
Other Products
SM511 HollySys Output Module, HollySys SM511 Module Shanghai Sijian Intelligent Technology Co., Ltd. is engaged in technical development, technical consultation, technical transfer in the fields of intelligent technology, information technology, and automation technology, as well as the sales of electrical equipment, automation equipment, electronic products, communication products, and electromechanical products. Industrial automation products: PLC, DCS, sensors, frequency converters, encoders, relays, servo drives, soft starters, touch screens. Brands involved in the products include: Eurotherm, Schneider, Siemens, ABB, SICK, P+F, E+H, Yokogawa, Yamakawa, Mitsubishi, Emerson, Honeywell, FANUC, GE, Eaton Electrical, CT,
SM511 HollySys Output Module, The PLC pulse frequency function reads the pulse frequency input from the high-speed counter, converts it into rotational speed, or converts the current counter value into cumulative revolutions. It outputs the converted value as an 8-digit hexadecimal number and can only be used with high-speed counter 0. When converting frequency to rotational speed, the rotational speed is calculated using the pulse frequency input from the high-speed counter and the number of pulses per revolution. When converting the current counter value to cumulative revolutions, the cumulative revolutions are calculated using the current counter value and the number of pulses per revolution. The specific steps for its use are as follows.
(1) Setting the use/non-use of the high-speed counter: Set [High-speed Counter 0 Use/Non-use] in the PLC system settings to "Use".
(2) Selection of counter mode: Select [High-speed Counter 0]/[Counting Mode] in the PLC system settings.
(3) Selection of numerical range mode: Select [High-speed Counter 0]/[Numerical Range Mode] in the PLC system settings. If the numerical range mode is set to ring mode, set [High-speed Counter 0]/[Ring Counter Maximum Value] in the PLC system settings.
(4) Selection of high-speed counter current value reset method: Select [High-speed Counter 0]/[Reset Method] in the PLC system settings.
(5) Execution of the PRV2 instruction: When converting frequency to rotational speed, operand C1 is the control data [Frequency to Rotational Speed Conversion: #0000]; operand C2 is the system setting [Number of Pulses per Revolution (Hα)]; operand D is the lower CH number of the conversion result storage destination. When converting the current counter value to revolutions, operand C1 is the control data [Current Counter Value to Cumulative Revolutions Conversion: #0001]; operand C2 is the coefficient setting [Number of Pulses per Revolution (Hα)]; operand D is the lower CH number of the conversion result storage destination.
| Industry Category | |
|---|---|
| Product Category | |
| Brand: | 和利時(shí) |
| Spec: | SM511 |
| Stock: | 66 |
| Manufacturer: | |
| Origin: | China / Shanghai / Pudongxinqu |