色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China DWYER Electromagnetic Flow Sensor IEF-SN-CND - China Supplier
China DWYER Electromagnetic Flow Sensor IEF-SN-CND - China Supplier

DWYER Electromagnetic Flow Sensor IEF-SN-CND

Price:¥6500
Industry Category: Electronic Components & Supplies/Sensors/Displacement Sensors
Product Category:
Brand: DWYER
Spec: IEF-SN-CND


Contact Info
  • Add:閔行七寶萬科云25棟, Zip: 201615
  • Contact: 劉曈
  • Tel:021-37776392
  • Email:69601155@QQ.com

Other Products

Description
Additional Information

DWYER Electromagnetic Flow Sensor IEF-SN-CND

The IEFB series is a field-adjustable insertion thermal energy meter that uses electromagnetic technology to accurately and reliably measure fluid velocity and energy consumption. The high-precision IEFB can be adjusted to fit pipe sizes from 4 to 10 inches (100 to 250 mm), while the standard-precision IEFB is suitable for pipe sizes from 4 to 36 inches (100 to 900 mm). The IEFB integrates a thermometer and a calculator into a single unit. The LCD display provides clear readings of meter values, including temperature and energy consumption, making it ideal for installation in chillers, boilers, and other heating and cooling applications. With high measurement accuracy and long service life, it minimizes annual operating costs. Additionally, it offers multiple output options, including selectable BACnet MS/TP or Modbus? RTU communication protocols via 2-wire RS-485, as well as standard analog, frequency, and alarm outputs. · Flexible field-configurable settings display (LCD integrated option or remote accessory A-IEF).

Monitoring chiller cooling output performance, DWYER Electromagnetic Flow Sensor IEF-SN-CND

The IEF series insertion electromagnetic flow transmitter is an adjustable insertion flow meter that, in addition to providing continuous signal output, employs electromagnetic technology for precise and reliable measurement of fluid velocity. This series is designed to deliver superior performance with simple installation and use. A single unit can be adjusted to fit pipe sizes from 4 to 36 inches (101.6 to 914.4 mm) and offers multiple output options, including selectable BACnet MS/TP or Modbus? RTU communication protocols, in addition to standard analog, frequency, and alarm outputs, communicating via 2-wire RS-485.
Field configurable, high precision, BACnet or Modbus protocol.

Medium: Compatible clean or dirty non-coating, conductive liquids.  

Range: 0-20 ft/s (0-6 m/s).

Wetted Materials: Body shaft/fittings: 316SS; Electrodes: 316SS; Electrode cover: Polymer/Polystyrene; O-ring: Silicone.

Accuracy: IEF-HX-K: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s). IEF-SX-X: ±1% FS.

Temperature Resistance: Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C).

Connection: 1" NPT or BSPT with full-port ball valve option accessories.

Pressure Rating: 400 psi (27.6 bar) @ 100°F (37.8°C).

Pressure Drop: < 0.1 psi at 12 ft/s in 4" (101.6 mm) or larger pipes.

Output: (1) Analog: 4-20 mA, 0-5 V, 0-10 V, or 2-10 V (display selectable);

(2) Pulse/Frequency: 0-15 V pulse, 0-500 Hz, or adjustable output (display selectable);

(3) Alarm: (1) Empty pipe detection or minimum/flow velocity (display selectable); (2) Reverse flow output indication.

Power Supply: 12-42.4 VDC, 0.25 A @ 24 VDC; 12-36 VAC.

Electrical Connection: Removable terminal block, model-selectable 1/2" female NPT conduit connection, PG 16 gland, or PG 16 gland with (2) 10' (3 m) 9-conductor 22 AWG rated cable; accessory cable length up to 200' (61 m) optional.

Display: 2" (5.08 cm) x 2" (5.08 cm) graphic LCD with backlight.

Conductivity: >20 microsiemens.

Housing: Powder-coated aluminum casting.

Enclosure: NEMA 6P (IP68) (non-display models); NEMA 4X (IP66) (LCD optional).

Certifications: UL, CE, NSF/ANSI 61 and 372.


Communication (-COM option)

Type: BACnet MS/TP or Modbus? RTU communication protocol (default disabled, display selectable).

Supported Baud Rates: 9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).

Device Load: 1/8 unit load.

Additional Specifications

Applicable Pipe Materials: Common plastic and metal pipes; such as carbon steel, stainless steel, copper, UPVC/PVDF, galvanized steel, mild steel, and brass*.

Pipe Sizes: IEF-HEX-X: 4 to 10" (101 to 254 mm); IEF-SX-X: 4 to 36" (101 to 914 mm).


Installation Position Requirements: Upstream >10 times diameter, downstream >5 times diameter.


*Brass fittings and pipes are not used with NSF-certified models.

Industry Category Electronic Components & Supplies/Sensors/Displacement Sensors
Product Category
Brand: DWYER
Spec: IEF-SN-CND
Stock: 122
Manufacturer:
Origin: China / Shanghai / Jinganqu
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 隆化县| 大方县| 万山特区| 赣州市| 伊宁县| 新津县| 深圳市| 汨罗市| 石阡县| 哈巴河县| 鄂州市| 晴隆县| 兴隆县| 石景山区| 广灵县| 柞水县| 古浪县| 四会市| 太仓市| 永城市| 壤塘县| 乌鲁木齐县| 波密县| 卢氏县| 新沂市| 三台县| 西峡县| 贺兰县| 罗源县| 尼木县| 双柏县| 革吉县| 万盛区| 焦作市| 谷城县| 阿拉善盟| 庄浪县| 光泽县| 琼海市| 淳化县| 澄迈县|