色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device - China Supplier
China Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device - China Supplier China Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device - China Supplier China Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device - China Supplier China Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device - China Supplier China Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device - China Supplier

Photovoltaic Direct-Flexible System Anti-Islanding Measures and Frequency/Voltage Emergency Control Device

Price:¥0.1
Industry Category: Energy
Product Category:
Brand: 芒種
Spec: 并網(wǎng)


Contact Info
  • Add:南京市棲霞區(qū)八卦洲街道中心路68號(hào), Zip: 210043
  • Contact: 小芒
  • Tel:15951634545
  • Email:15951634545@163.com

Other Products

Description
Additional Information

Anti-Islanding Measures and Frequency-Voltage Emergency Control Devices

(1) Inverter Anti-Islanding Protection

Inverters must have anti-islanding protection functions. The anti-islanding protection for inverters in photovoltaic power stations primarily includes detection methods such as frequency deviation, power variation, and voltage phase jumps, with an operating time between 100ms and 1s. Islanding phenomenon protection is the most critical and highest-priority protection in grid-connected inverter protection. It is required that the photovoltaic system must cease supplying power to the grid within 2 seconds after grid voltage loss.

(2) Frequency-Voltage Emergency Control Device

During an islanding event, frequency and voltage will undergo abrupt changes. For this phase, a frequency-voltage emergency control device must be installed on the 10kV outgoing line side of the photovoltaic power station. This device should feature slip differential blocking functionality and the ability to detect short circuits.

This frequency-voltage emergency control device is used for emergency control of grid frequency and voltage under extreme conditions. It is applicable in scenarios where abnormal grid frequency or voltage requires urgent control measures, such as low-frequency/low-voltage separation or high-frequency generator tripping. The main functional requirements are as follows:

1. Low-frequency and low-voltage separation function: When the grid frequency drops to the set value, the device should be capable of initiating separation to restore frequency to normal levels. In cases where a grid with a significant active power deficit experiences severe faults or separation, voltage may drop critically and fail to recover. Under such conditions, low-voltage separation should be employed if low-frequency separation fails to operate or in situations of reactive power imbalance.

2. High-frequency and high-voltage generator tripping function: When the system experiences over-frequency or over-voltage conditions, the device should be able to perform generator tripping, separation, or rapid steam valve control.

3. Out-of-step oscillation separation function: If a power plant loses synchronization with the main system and experiences out-of-step oscillations, the device must simultaneously trip all parallel connections between the generating units and the main grid, isolating the plant's primary output section—meaning both lines are separated (during maintenance, only the operational tie-line is separated).

4. Measurement function: The device should be capable of simultaneously measuring three-phase voltage, three-phase current, frequency, active power, reactive power, and phase angle across two bus sections or two tie-lines, serving as the basis for decision-making.

5. Remote function: The device must include reserved communication interfaces or remote trip contact inputs for executing remote trip commands or load shedding commands. It should also be able to send load shedding or separation commands to remote locations.

6. The device should record essential information (such as fault waveform data) and transmit it via interfaces. The recorded information must not be lost and should be reproducible. The content of the recorded data is primarily used to verify whether all parts of the device are functioning correctly and whether operations are performed as intended.

7. The device should feature an automatic time synchronization function.


Jiangsu Mangzhong Construction Co., Ltd. is a comprehensive energy service provider specializing in the photovoltaic field, dedicated to being a smart energy enterprise engaged in photovoltaic power station investment, development, design, construction, intelligent operation and maintenance, professional consulting services, and photovoltaic equipment recycling.

Company Name: Jiangsu Mangzhong Construction Co., Ltd.

Business Scope: EPC for photovoltaic power stations and investment in solar power stations

Company Landline: 025-5888 3737   

Mobile Number: 159 5163 4545

Company Website: http://www.mangz.cn

Industry Category Energy
Product Category
Brand: 芒種
Spec: 并網(wǎng)
Stock: 10000
Manufacturer:
Origin: China / Jiangsu / Nanjingshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Me 柳江县| 兴安县| 竹溪县| 古浪县| 余干县| 依兰县| 共和县| 岢岚县| 平罗县| 邵阳市| 苏尼特右旗| 龙游县| 女性| 临安市| 临澧县| 时尚| 丰城市| 靖边县| 蓝田县| 台东市| 水城县| 邵阳县| 霍林郭勒市| 北川| 子洲县| 右玉县| 始兴县| 宁南县| 永城市| 错那县| 长海县| 辰溪县| 马龙县| 封开县| 曲靖市| 昂仁县| 额尔古纳市| 高陵县| 道真| 若尔盖县| 衡水市|