色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China LC72-TUR Online Turbidity Meter - China Supplier
China LC72-TUR Online Turbidity Meter - China Supplier

LC72-TUR Online Turbidity Meter

Price:Negotiable
Industry Category: Instruments & Meters
Product Category:
Brand:
Spec:


Contact Info
  • Add:宜興市高塍鎮(zhèn)江南路126號(hào), Zip: 214214
  • Contact: 余麗蘭
  • Tel:0510-87838003
  • Email:wxzjhb@163.com

Other Products

Description
Additional Information

I. Main Features ◆ User-Friendly Interface Design The LC72-TUR Turbidity Meter features a 320×240 ultra-large dot matrix LCD display (currently the highest resolution dot matrix LCD in the industry) with a fully Chinese operation menu. Even without the manual, users can easily and intuitively operate the device. The display interface simultaneously shows the current turbidity value, alarm status, cleaning status, current output, communication status, and other information. ◆ Data Recording Function The LC72-TUR Turbidity Meter includes a data logging function, serving as a replacement for paperless recorders. The recording interval can be set from 10 minutes to 24 hours. Recorded values can be reviewed by entering the corresponding page number to check data from different time periods. ◆ Password Protection for Operation Any configuration or calibration of the LC72-TUR Turbidity Meter requires a password, effectively preventing misuse by operators. ◆ Anti-Interference Current Output Most similar products suffer from unstable current output, especially when used in environments with frequency converters or PLCs, where the output fluctuates uncontrollably. Our LZ-7120D model employs a new circuit design and high-speed optocoupler isolation technology to completely resolve current output instability. ◆ Factory Reset Function If users are unsure whether the device’s settings or calibration data are correct, they can perform a factory reset in the corresponding operation interface to restore the device to its original factory state (this feature is exclusive to Laner’s instruments). ◆ Multiple Special Function Settings The LC72-TUR Turbidity Controller offers various unique function settings, including online value correction, factory reset, and four sets of relay control, among others. ◆ Audible and Visual Feedback for Key Operations In addition to the keypress sound feedback found in older models, the LC72-TUR Turbidity Controller also features blue high-brightness LED visual feedback. This is particularly advantageous in noisy industrial environments. ◆ Programmable Analog Output Range The LC72-TUR Turbidity Controller comes standard with one 4–20mA output and supports an optional second 4–20mA output. Both outputs are programmable, allowing users to set the output range. The factory default is zero to full scale, but any range within the full scale can be customized. Both outputs can also be set for reverse output (20.00–4.00mA). ◆ Two Independent Relay Hysteresis Values The LC72-TUR Turbidity Controller is designed with two independent relay hysteresis values, addressing the conflict of using a single hysteresis value for different controls. The high and low points have separate hysteresis values, labeled Hd and Ld. ◆ Optional Four Relay Outputs The LC72-TUR Turbidity Controller supports up to four optional relay outputs, enabling control of up to six dosing devices. ◆ Automatic Data Check upon Startup After powering on, the device automatically checks whether stored data falls within the normal range. If not, it automatically restores factory settings to ensure error-free operation. Technical Parameters: Measurement Range: 0.00–20.00 NTU, 0.0–200.0 NTU, 0–2000 NTU (optional) Resolution: 0.01 NTU, 0.1 NTU, 1 NTU Display: 320×240 ultra-large dot matrix LCD with backlight (currently the highest resolution dot matrix in the industry) Light Source: Laser diode (LED) – 10-year lifespan Control Range: Any value within the full scale for two relays Automatic Cleaning Time: 1 second – 99 minutes 59 seconds (user-configurable) Cleaning Interval: 1–720 minutes (user-configurable) Signal Output: 4–20mA (reversible) Communication Interface: Bidirectional RS-485, Modbus (optional) Maximum Water Pressure: Built-in pressure regulating valve, maximum pressure 1380 kPa Sample Flow Rate: 100 mL/min – 1 L/min Sample Temperature: +1 – +50°C Operating Voltage: AC 220V ±10%, 50/60 Hz Dimensions: 144×144×145 mm Installation Method: Embedded installation Operating Environment: ① Ambient Temperature: -5 – 55°C ② Relative Humidity: ≤90% ③ No strong magnetic interference except for the Earth’s magnetic field

Industry Category Instruments & Meters
Product Category
Brand:
Spec:
Stock:
Origin:
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Me 洮南市| 修武县| 常德市| 汝南县| 大方县| 商水县| 深圳市| 岗巴县| 宜昌市| 兖州市| 鄯善县| 阿拉尔市| 马边| 张家口市| 确山县| 沾化县| 志丹县| 长泰县| 荔浦县| 西和县| 旬阳县| 赤壁市| 和平县| 叶城县| 济阳县| 厦门市| 宁津县| 银川市| 内黄县| 武义县| 香河县| 龙里县| 常山县| 鄯善县| 泾川县| 金湖县| 金坛市| 宣城市| 香格里拉县| 云梦县| 将乐县|