色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China Dissolved Oxygen Electrode - China Supplier
China Dissolved Oxygen Electrode - China Supplier

Dissolved Oxygen Electrode

Price:Negotiable
Industry Category: Instruments & Meters
Product Category:
Brand:
Spec:


Contact Info
  • Add:宜興市高塍鎮(zhèn)江南路126號, Zip: 214214
  • Contact: 余麗蘭
  • Tel:0510-87838003
  • Email:wxzjhb@163.com

Other Products

Description
Additional Information

Introduction to Dissolved Oxygen Electrode Utilizing a polarographic electrode, the anode is made of Ag/AgCl and the cathode of platinum (Pt), with a special electrolyte solution filled between them. The electrode is encapsulated by a silicone rubber permeable membrane. During measurement, a polarization voltage of 675 mV is applied between the electrodes. Oxygen permeates through the membrane and is consumed at the cathode, while an equivalent amount of oxygen is generated at the anode. This dynamic process continues until the oxygen partial pressures on both sides reach equilibrium. At this point, the current between the electrodes is proportional to the oxygen partial pressure. The secondary meter detects this current and, through a series of conversions, obtains the oxygen concentration and content. Simultaneously, an NTC (Negative Temperature Coefficient thermistor) detects the temperature of the measured liquid. The secondary meter samples the data and performs temperature compensation, converting the oxygen concentration or content to values at 25°C. Cathode reaction: O? + 2H?O + 4e? → 4OH? Anode reaction: 4Ag + 4Cl? → 4AgCl + 4e? Applications Dissolved oxygen electrodes can be used to monitor processes where oxygen content affects reaction speed, process efficiency, or the environment, such as in aquaculture, bioreactions, environmental testing (lakes, streams, oceans), water/wastewater treatment, and wine production. The T401ppm dissolved oxygen electrode offers high stability and reliability, suitable for use in harsh environments with minimal maintenance. Troubleshooting When using polarographic electrodes, preheat for at least 15–30 minutes before calibration or measurement. To ensure no bubbles are present in the electrolyte of the membrane, the ASI membrane cap is designed to expel all air from the liquid chamber when installing the membrane head. No bubbles should remain on the membrane surface, as they may be misinterpreted as oxygen-saturated samples. Even when using instruments with automatic temperature compensation, calibrate the electrode at a temperature close to that of the sample solution. Calibrate the electrode in air, using air as the 100% saturated dissolved oxygen reference point. Since the electrode consumes oxygen, the oxygen concentration at the probe surface momentarily decreases. Therefore, it is essential to stir the solution during measurement. Replace the membrane if it is damaged. Technical Parameters: Measurement range: 0–20 mg/L (ppm), 0–200% Operating temperature: 0–130°C Temperature compensation range: 0–130°C Measurement principle: Amperometric sensor Membrane thickness: 50 μm Electrode material: UPVC or 316L Sensing material: POM outer tube, silver tube, gold wire with temperature compensation function Response time: 90% in 60 seconds (upscale, at 20°C) Polarization time: 2 hours Minimum flow rate: 2.5 cm/s Cable length: Standard 10 m Installation method: 3/4-inch pipe thread installation Standard configuration: One electrode, two spare membrane heads, one bottle of specialized electrolyte solution.

Industry Category Instruments & Meters
Product Category
Brand:
Spec:
Stock:
Origin:
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Me 休宁县| 海门市| 池州市| 葵青区| 嵊州市| 巍山| 商南县| 武冈市| 且末县| 海口市| 昌都县| 泰安市| 威宁| 禹城市| 喀喇| 恭城| 定南县| 磐安县| 五家渠市| 陈巴尔虎旗| 祁东县| 济宁市| 兰考县| 乌鲁木齐县| 壤塘县| 罗山县| 青海省| 京山县| 阿鲁科尔沁旗| 云和县| 衡阳县| 尼木县| 清徐县| 樟树市| 岑溪市| 南通市| 稻城县| 江阴市| 铜梁县| 珲春市| 兴海县|